NT6200 X-γ dosimeter-radiometer

Email Me
Product Introduction
Chinacoal08

NT6200 MODEL is a portable X-γ radiation measuring instrument. Build in a high sensitive gamm beta Geiger-Muller counter. With fast response, wide measuring range characteristicsUsing for measuring X-ray ,gamma  radiation. It’s  a multipurpose radiation dose rate measuring instrument.

Purpose for use

-Measurement of gamma radiation ambient dose equivalent rate; 
-Measurement of gamma radiation ambient dose equivalent; 
-Measurement of surface beta-particles flux density; 
-Measurement of ambient dose equivalent accumulation time; 
-Real time measurement (clock).
Applications
-Nuclear facilities around environmental radiation detection
- The soil surface radiation pollution detection
- Agricultural radiation pollution detection
- Ore, building materials radioactive detection
- Personal dose monitoring alarm
- Industrial X, gamma radiation detection
- Radiation medical treatment place radiation detection
- Cobalt source, electronic accelerator irradiation place radiation detection
- Radioactive radiation laboratory detection

Features

- Large area digital LCD display backlight;
- Built-in gamma, beta sensitive Geiger-Muller counter;
- Simultaneously dose rate and cumulative dose measurement
- Automatic setting of measurement intervals and ranges;
- The maximum dose rate values keep function
- Automatic setting of measurement intervals and ranges;
- Automatic save dose value.
-Programmable dose rate alarm and cumulative dose alarm threshold
- Programmable voice, light and vibration  alarm  way
- Battery voltage and low battery indication;
- Automatic failure detection function

Specifications

-Measurement ranges:
  dose equivalent rate (137Cs): 0.01 μSv/h100mSv/h
  dose equivalent (137Cs): 0.01uSv~9999Sv
-Energy ranges
  X and Gamma radiation: 40Kev3.0Mev
- Energy dependence: ≤±25%relative to 137Cs
- Relative errors : ≤±10%in  20uSv/h
- Dose rate and dose alarm threshold value: full range can be adjusted
- Protective alarm response time: not more than 3 seconds (in 10 uSv/h)
-Display unit
Dose rate : uSv/h,mSv/h,Sv/h automatic conversion
Dose : uSv , mSv ,Sv automatic conversion
-Battery : One AAA battery
- Operating temperature range : -20°С~+50°С
- Weight and Dimensions: 80g  ,80*55*15 mm 


Specifications

Measurement ranges
dose equivalent rate (137Cs)
0.01 μSv/h100mSv/h
dose equivalent (137Cs)
0.01uSv~9999Sv
Energy ranges
X and Gamma radiation
40Kev3.0Mev
Energy dependence
Less than or equal ±25%relative to 137Cs
Relative errors 
Less than or equal ±10%in  20uSv/h
Dose rate and dose alarm threshold value
full range can be adjusted
Protective alarm response time
not more than 3 seconds (in 10 uSv/h)
Display unit
Dose rate
uSv/h,mSv/h,Sv/h automatic conversion
Dose 
uSv , mSv ,Sv automatic conversion
Battery
One AAA battery
Operating temperature range
-20~+50 Degrees Celsius
Weight
80g 
Dimensions
80*55*15 mm 